Symptoms

In order to change title of login page, provider added customized locale file in PCP > System > Settings > Locales > Locale > Customized Locale Files with the following content:

<?xml version="1.0" encoding="UTF-8"?>
<locale code="en_US">
 <section>
    <name>PanelBundle.properties</name>
        <data>
           <entry>
                <keyword>BRANDED.BROWSER_WINDOW_TITLE</keyword>
                <phrase>Example</phrase>
                <comment></comment>
           </entry>
      </data>
 </section>
</locale>

However, the title of login page of Odin Automation was not changed.

Cause

Due to software-related issue POA-111287, localized BRANDED.BROWSER_WINDOW_TITLE is not recognized on login page in OA version 7.0. This issue was passed for further investigation to the Engineering team.

Resolution

In order to change title of login page, please create an XML file with the following content and add it to System > Settings > Locales > Locale > Customized Locale Files. Please note that in addition to OA 6.0, the file should contain additional variable declarations:

<?xml version="1.0" encoding="UTF-8"?>
<locale code="en_US">
<section>
<name>PanelBundle.properties</name>
    <data>
            <entry>
                <keyword>BRANDED.BROWSER_WINDOW_TITLE</keyword>
                <phrase>Example</phrase>
                <comment></comment>
            </entry>
            <entry>
                <keyword>LOGIN.CAPTION</keyword>
                <phrase>example</phrase>
                <comment></comment>
            </entry>
    </data>
 </section>
</locale>

5356b422f65bdad1c3e9edca5d74a1ae caea8340e2d186a540518d08602aa065 e12cea1d47a3125d335d68e6d4e15e07 0871c0b47b3b86ae3b1af4c2942cd0ce 1941880841f714e458ae4dc3d9f3062d

Email subscription for changes to this article
Save as PDF