Article ID: 130634, created on Apr 13, 2017, last review on Apr 13, 2017

  • Applies to:
  • Operations Automation 7.0
  • Operations Automation 6.0

Symptoms

The Upgrading resources of application task does not proceed with execution after its start.

There is no task activity observed in /var/log/pa/core.log on the Management node.

At the same time the Synchronize resource usage for instances of APS applications periodic task is running.

Cause

APS resource usage calculation process blocks all other operations with application instances, which leads to delays processing other APS application tasks.

This behavior is considered as a software issue POA-107476.

Resolution

To avoid the issue, change Synchronize resource usage task execution period, making sure the task does not run at the moment of an application upgrade.