Search Engine: Elastic

Article ID: 129818, created on Nov 7, 2016, last review on Nov 7, 2016

  • Applies to:
  • Operations Automation 6.0
  • Operations Automation 5.5

Symptoms

Error appears in Event Viewer Application log on each Windows node upon OA agent restart:

Log Name:      Application
Source:        POA
Date:          04/11/2014 07:24:05
Event ID:      6
Task Category: None
Level:         Error
Keywords:      Classic
User:          HOSTING\pem_admin
Computer:      WPE01.hosting.local
Description:
The description for Event ID 6 from source POA cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.

It occurs on all Windows hosts. OA Agent actually works fine, so the issue does not affect provisioning. Agent version on all servers is up to date. The following error can be found in poa.log on Windows servers when restarting OA Agent:

Nov  5 06:33:37 WPE01 : ERR [SYSTEM 0:42160:9ed4 lib]: [SDK::IPAddress::getHostIPAddressDescriptions] SDK::IPAddress: system exception, ID 'IDL:omg.org/CORBA/UNKNOWN:1.0'
Unknown vendor minor code id (0), minor code = 0, completed = YES
Nov  5 06:33:37 WPE01 : INF [SYSTEM 0:42160:9ed4 lib]: [SDK::IPAddress::getHostIPAddressDescriptions] Failed to narrow object IOR:010000001900000049444c3a495041646472657373507269766174653a312e300000000001000000000000009c000000010102490f0000003139322e3136382e35302e32303900e0a3204ef04800000014010f004e5550000000250100000001000000526f6f74504f41004f626a6563744d616e6167657273006368696566001f0000000100000053444b3a3a4950416464726573732f3302000000000000000800000001000000004f41540100000018000000010000000100010001000000010001050901010000000000
Nov  5 06:33:37 WPE01 : DBG [SYSTEM 0:42160:9ed4 lib]: [SDK::IPAddress::getHostIPAddressDescriptions] {module_id="Kernel"; code="10"} The operation can not be completed because the following component is missing                                     or is not running: SDK::IPAddress (sc_name '', sc_id #3)
Nov  5 06:33:37 WPE01 : ERR [SYSTEM 0:42160:9ed4 pleskd]: [syncHostNICs] syncHostNICs has failed for host ID #48: user exception, ID 'IDL:Plesk/ExSystem:1.0'.

Cause

IORs are different on slave nodes and on the OA Management Node.

Resolution

  1. Check IOR on the OA Management Node:

    select sr.ior from service_references sr join interfaces i on (sr.interface_id = i.interface_id) where i.service_type = 'SDK::IPAddress';
    
    IOR:010000002500000049444c3a506c65736b2f53656375726974794d616e61676572507269766174653a312e30000000000100000000000000a0000000010102b30f0000003139322e3136382e35302e3230390000a3204c3a4900000014010f004e5550000000250100000001000000526f6f74504f41004f626a6563744d616e616765727300636869656600300000000100000053656375726974794d616e616765722f336d656e02000000000000000800000001313335004f41540100000018000000010000000100010001000000010001050901010000000000
    (1 row)
    
  2. compare it with IOR shown in the error mentioned above. If they are different, then do the following steps:

    • stop OA Agent on all affected nodes using the command net stop pem
    • restart pem/pau services on the OA Management Node
    • start OA Agent on all affected nodes using the command net start pem

5356b422f65bdad1c3e9edca5d74a1ae caea8340e2d186a540518d08602aa065 e12cea1d47a3125d335d68e6d4e15e07 956c448bddc7e1f3585373687602379f 6f1456866eed87488c0f02b298a741c0 5b048d9bddf8048a00aba7e0bdadef37 2554725ed606193dd9bbce21365bed4e