Article ID: 129309, created on Aug 24, 2016, last review on May 23, 2017

  • Applies to:
  • Odin Business Automation Standard 4.5

Symptoms

Usage for non-additive OA resources calculated incorrectly on OBAS side. It does not match with corresponding data from OA.

Cause

Such behavior was classified as the software issue PBAS-30348 and was fixed in OBAS 4.5.7 release.

Resolution

To resolve the issue, please upgrade to 4.5.7 as described in How to upgrade OBAS system to the latest available version.

Workaround

For OBAS 4.5.6:

Please download 64-bit hotfix or 32-bit hotfix depending on your OS and install it by running the commands below .

64-bit OS:

# rpm -Uvh hspc-pa-4.5.6-49.swsoft.x86_64.rpm
# service hspcd restart

32-bit OS:

# rpm -Uvh hspc-pa-4.5.6-49.swsoft.i386.rpm
# service hspcd restart

For OBAS 4.5.5:

Please download 64-bit hotfix or 32-bit hotfix depending on your OS and install it by running the commands below .

64-bit OS:

# rpm -Uvh hspc-pa-4.5.5-62.swsoft.x86_64.rpm
# service hspcd restart

32-bit OS:

# rpm -Uvh hspc-pa-4.5.5-62.swsoft.i386.rpm
# service hspcd restart

Warning: Restart of the hspcd service will cause OBAS downtime for about 10-60 seconds.