Article ID: 124243, created on Jan 22, 2015, last review on Jan 22, 2015

  • Applies to:
  • Plesk Automation 11.5

Symptoms

Pre-migration check fails with error:

ppa-transfer check config.ini
Error message or request description : [ERROR]  | Error while checking target panel configuration and connections: 'File contains parsing errors: <???>
    [line 13]: u' enabled = on\n'
    [line 17]: u' filter.priority = 7\n'
    [line 21]: u' show.util_exec = on\n''.

Cause

ppa-transfer cannot parse the control charachters in CP configuration file /usr/local/psa/admin/conf/panel.ini

Resolution

Re-save the configuration /usr/local/psa/admin/conf/panel.ini file properly, so that there is no control characters.

NOTE: The ppa-transfer will not work with debug logging turned on. In order to proceed with migration it will be required to turn debug off.

33a70544d00d562bbc5b17762c4ed2b3 caea8340e2d186a540518d08602aa065 e0aff7830fa22f92062ee4db78133079

Email subscription for changes to this article
Save as PDF