Article ID: 119881, created on Jan 29, 2014, last review on Apr 30, 2014

  • Applies to:
  • Business Automation 5.5

Symptoms

Confirmation email the user received has blank/incorrect value for the confirmation URL. In the notification template the placeholder @@ConfirmationURL@ is used. How to correct the URL?

Resolution

  1. Set the correct values in the e-mail settings:

    Home > System > Settings > Events > Notifications > Security > Email Settings tab

    Return Host is the URL of PBA control panel. Email Confirmation Required shall be set to Yes.

  2. Indicate the proper template:

    Home > System > Settings > Notifications > Common Notification Settings

    Email Confirmation Template

  3. Resend the confirmation notification to the user, the button "Resend Confirmation E-mail" shall be used (not "Send Notification").