Symptoms

A container migration task is failing with the error:

Can't connect to source node (<IP>) : can not read reply from destination node

where <IP> address is external.

Cause

The source Virtuozzo node cannot connect to the destination Virtuozzo node through external interface.

Resolution

  1. Change <primary_address> parameter value in the PVA agent configuration file (usually /var/opt/pva/agent/etc/vzagent.conf) to internal IP address on both nodes to be sure there will be no issue with inappropriate IP selection anymore.

  2. Check that no tasks are scheduled for both nodes in Operations Automation, as they will fail during pva agent service restart.

  3. Restart pva agent service on both nodes:

    ~#/etc/init.d/pvaagentd restart
    
  4. Restart the task in Operations Automation.

ac82ce33439a9c1feec4ff4f2f638899 caea8340e2d186a540518d08602aa065 5356b422f65bdad1c3e9edca5d74a1ae 2554725ed606193dd9bbce21365bed4e e12cea1d47a3125d335d68e6d4e15e07 0889ab60fa6494de107aa7338c3c38b6 2897d76d56d2010f4e3a28f864d69223 319940068c5fa20655215d590b7be29b 5b048d9bddf8048a00aba7e0bdadef37 0efe2234e2ce513f2186f26c68447702 0871c0b47b3b86ae3b1af4c2942cd0ce 1941880841f714e458ae4dc3d9f3062d 956c448bddc7e1f3585373687602379f 6f1456866eed87488c0f02b298a741c0