Symptoms

  • Parallels Plesk Sitebuilder node registered in Parallels Business Automation - Standard 3.3 (former HSPcomplete) system was upgraded to 4.1 version;
  • New Parallels Plesk Sitebuilder 4.1 (for Unix) node registered in Parallels Business Automation - Standard system
  • Parallels Plesk Sitebuilder 4.1 (for Unix) node synchronization fails
  • It is not possible to order Sitebuilder services from Online Store

Cause

API changes in Parallels Plesk Sitebuilder 4.1 (for Unix) version.
 

Resolution

After Parallels Plesk Sitebuilder node upgrade to 4.1 version or after registration Parallels Plesk Sitebuilder 4.1 node in Parallels Business Automation - Standard 3.3 system it is required to add api_old_paging_algo parameter under [general] section in Sitebuilder configuration <sb-root>/config file on Sitebuilder node (it is usually located in /usr/local/sitebuilder/config on RedHat-based systems or in /opt/sitebuilder/config on Debian-based systems):[general]

api_old_paging_algo = true


 

 