Article ID: 128638, created on Apr 10, 2016, last review on Apr 10, 2016

  • Applies to:
  • Operations Automation 5.5

Symptoms

I tried to register new Windows hardware node by going to OA PCP > Infrastructure > Hardware Nodes > Add New Node > Windows Shared, but the error was shown after I entered IP address/password and clicked Next:

Error: Password should not contain '^'. 

Cause

The inability to register Windows hardware nodes with '^' in passwords was implemented in scope of POA-76325

Resolution

Update administrator password on Windows hardware node: it should not contain ^. This symbol cannot be used in command lines with cmd /c due to limitations of command line parser.

NOTE: in OA 5.4 verification of passwords of Windows AD accounts was done only when registering Windows Shared hardware nodes, since OA 5.5 it has been implemented for all other cases too.