Article ID: 127905, created on Dec 27, 2015, last review on Jun 27, 2016

  • Applies to:
  • Odin Business Automation Standard 4.5

Symptoms

After OBAS upgrade to 4.5.5-31 version Log in to CP, Log in to RCC, Log in to Parallels Plesk Control Panel, Login to PCP buttons are opening in a new browser window instead of a new tab.

Cause

Such behavior is considered as internal software issue PBAS-30203. It was fixed in OBAS 4.5.6

Resolution

To resolve the issue, please upgrade to 4.5.6 as described in How to upgrade OBAS system to the latest available version.

Hotfix for OBAS 4.5.5

For 64-bit operating systems:

Download rpm packages:

hspc-core-4.5.5-40.swsoft.x86_64.rpm

hspc-infstr-manager-4.5.5-40.swsoft.x86_64.rpm

hspc-root-4.5.5-40.swsoft.x86_64.rpm

and install them:

# rpm -Uhv hspc-core-4.5.5-40.swsoft.x86_64.rpm hspc-infstr-manager-4.5.5-40.swsoft.x86_64.rpm hspc-root-4.5.5-40.swsoft.x86_64.rpm
# service hspcd restart

Warning: Restart of the hspcd service will cause OBAS downtime for about 10-60 seconds.

For 32-bit operating systems:

Download rpm packages:

hspc-core-4.5.5-40.swsoft.i386.rpm

hspc-infstr-manager-4.5.5-40.swsoft.i386.rpm

hspc-root-4.5.5-40.swsoft.i386.rpm

and install them:

# rpm -Uhv hspc-core-4.5.5-40.swsoft.i386.rpm hspc-infstr-manager-4.5.5-40.swsoft.i386.rpm hspc-root-4.5.5-40.swsoft.i386.rpm
# service hspcd restart

Warning: Restart of the hspcd service will cause OBAS downtime for about 10-60 seconds.