Symptoms

After updating BA to 6.0 additional configuration is required

Cause

Otherwise APS screens will not work in BA Online store

Resolution

Perform the following actions to update configuration files on the Business Automation Application host:

Log in to the Business Automation Application host.

In the file:

/etc/httpd/conf.d/ssl.conf.inc

add the following lines into the VirtualHost section:

#added by connect_to_poa.pl
ServerAlias BA_HOST
ProxyPass /aps http://OAMN_IP:8080/aps

where BA_HOST is Host name or IP address of BA application server, OAMN_IP is the IP address of Operations Automation Management node host

Restart the httpd service:

service httpd restart

Note

This change does not effect any security configuration