Article ID: 126955, created on Sep 21, 2015, last review on Sep 21, 2015

  • Applies to:
  • Odin Business Automation Standard 4.5

Symptoms

On a remote store installed into Plesk Error: STRING NOT FOUND is shown instead of all interface text strings.

Cause

OBAS store localization files are corrupted or absent on the Plesk server.

Resolution

Store localization files are stored in /var/www/vhosts/storedomain.tld/httpdocs/i18n/ folder, where storedomain.tld is a name of the store domain. Let us say that the English localization is broken. To fix it, please copy the /var/opt/hspc-store/i18n/EN/hspc-store-basic.xml file from the OBAS server to /var/www/vhosts/storedomain.tld/httpdocs/i18n/EN/ on the Plesk server and make sure its permissions and ownership match the ones of the parent directory.