Article ID: 125689, created on May 31, 2015, last review on Jun 22, 2015

  • Applies to:
  • Plesk Automation 11.5

Symptoms

Changing Hosting Settings or FTP user password via branded CCP for domain fails with error:

The proxy server received an invalid response from an upstream server

or

Bad Gateway
Web server received an invalid response while acting as a gateway or proxy server.

Cause

Operation for domain reconfiguration takes much time and exceeds web server time limits.

Resolution

  1. Increase the following limits on Plesk Automation (PA) management node:

    Before:
    # grep -w "Timeout" /etc/httpd/conf/httpd.conf | grep -v "#"
    Timeout 300
    
    After:
    # grep -w "Timeout" /etc/httpd/conf/httpd.conf | grep -v "#"
    Timeout 1200
    
  2. Restart httpd service:

    # /etc/init.d/httpd restart
    Stopping httpd:                                            [  OK  ]
    Starting httpd:                                            [  OK  ]
    