Article ID: 125545, created on May 18, 2015, last review on May 10, 2016

  • Applies to:
  • Operations Automation 6.0

ColdFusion service is not supported beginning from Odin Automation Premium 7.0 and it will be removed during the upgrade to Odin Automation Premium 7.0.

In order to prepare for upgrade to Odin Automation Premium 7.0, perform the following steps:

  1. Unprovide all 'ColdFusion 6, 7, 8' resources using any appropriate way: set the resource limit to zero in all subscriptions directly, change the corresponding Service Plans in Business Automation and apply these changes to Operations Automation or by migrating to other plans without the resource.
  2. Wait until all unprovisioning tasks are processed.
  3. Remove the following packages from host(s): IISColdFusion6Support (other), IISColdFusion7Support (other), IISColdFusion8Support (other).
  4. Unregister the node(s) from Service Automation, if necessary.

Important: During uninstalling CF packages from hosts, the issue with the failed tasks will appear, check the KB 127069 for resolution.