Article ID: 124243, created on Jan 22, 2015, last review on Jan 22, 2015

  • Applies to:
  • Plesk Automation 11.5

Symptoms

Pre-migration check fails with error:

ppa-transfer check config.ini
Error message or request description : [ERROR]  | Error while checking target panel configuration and connections: 'File contains parsing errors: <???>
    [line 13]: u' enabled = on\n'
    [line 17]: u' filter.priority = 7\n'
    [line 21]: u' show.util_exec = on\n''.

Cause

ppa-transfer cannot parse the control charachters in CP configuration file /usr/local/psa/admin/conf/panel.ini

Resolution

Re-save the configuration /usr/local/psa/admin/conf/panel.ini file properly, so that there is no control characters.

NOTE: The ppa-transfer will not work with debug logging turned on. In order to proceed with migration it will be required to turn debug off.

Search Words

Error message or request description : [ERROR] | Error while checking target panel configuration and connections: 'File contains parsing errors: <???>

File contains parsing errors: <???>

File contains parsing errors

Error while checking target panel configuration and connections

33a70544d00d562bbc5b17762c4ed2b3 caea8340e2d186a540518d08602aa065 e0aff7830fa22f92062ee4db78133079

Email subscription for changes to this article
Save as PDF