Article ID: 123433, created on Nov 6, 2014, last review on Nov 6, 2014

  • Applies to:
  • Business Automation 5.4

Symptoms

Attempt to synchronize Online Store in PBA Provider Control panel produces error:

Synchronization failed with error: Error while transmission of the stores.ini body. Didn't receive 200 OK from remote server..

Cause

Wrong IP address of the PBA-E application host is specified in the /usr/local/bm/templatestore/conf/params.inc on PBA-E store host.

Resolution

Please correct the IP in /usr/local/bm/templatestore/conf/params.inc.

Search Words

Didn't receive 200 OK from remote server

Error while transmission of the stores.ini body

198398b282069eaf2d94a6af87dcb3ff caea8340e2d186a540518d08602aa065 e12cea1d47a3125d335d68e6d4e15e07 210d017ddc3a076d22f0f865b1cf0730 92711db0799e8aefe8e51f12dace0496

Email subscription for changes to this article
Save as PDF