Article ID: 121237, created on Apr 22, 2014, last review on Jun 23, 2015

  • Applies to:
  • Operations Automation 5.5
  • Operations Automation 5.4
  • Business Automation 5.4


  • OA ( Odin Automation ) 5.5 is integarted with BA ( Business Automation ) 5.4;
  • Attempt to activate "Directory Synchronization" (AD Sync) fails:

    Failed to alter service state: Activated (PBA reported error while trying to add account member. Error: -1, 'Not enough space to store data in buffer.'.)


API method UserWithIDAdd_API fails because the password hash is passed, but in BA 5.4 there is a restriction for the password length (53 symbols). The issue is considered a bug #POA-84303.


Contact Odin Technical Support or upgrade BA to 5.5 .