Article ID: 120475, created on Mar 8, 2014, last review on May 11, 2014

  • Applies to:
  • Plesk Automation 11.5

Symptoms

Pem service does not start. From /var/log/poa.debug.log, I get error:

 ERR [SYSTEM 1:4376:b4dac740 lib]: [main] ExSystem: module_id:'Common', ex_type_id:'1',Message:'Internal error: Problem with CORBA initialization. Please check Agent configuration in pleskd.props file. Make sure that endpoint addresses 1.2.3.4 and port 8352 are not used by another process.', deprecated_codes = (0, 0), properties = { reason: 'Problem with CORBA initialization. Please check Agent configuration in pleskd.props file. Make sure that endpoint addresses 1.2.3.4 and port 8352 are not used by another process', }

Cause

Incorrect IP address or other settings are set in /usr/local/pem/etc/pleskd.props.

Resolution

  1. Check communication IP address in /usr/local/pem/etc/pleskd.props:

    orb.endpoint.port=8352
    orb.endpoint.addresses=1.2.3.4
    communication.ip=1.2.3.4
    
  2. Make sure that this address exists on your server:

    ifconfig |grep 1.2.3.4
    

33a70544d00d562bbc5b17762c4ed2b3 e0aff7830fa22f92062ee4db78133079 caea8340e2d186a540518d08602aa065

Email subscription for changes to this article