Article ID: 120151, created on Feb 15, 2014, last review on Apr 29, 2014

  • Applies to:
  • Operations Automation 5.5

Symptoms

PACI container is not manageable trough Customer CP in POA. Stop and Start operations fail with error "Failed to stop/Failed to start"

Cause

From PACI-vm2vf.log:

  <Vm2VfCallback>
); reqId=88850; corbaReqId=1113178.
2014-02-11 20:13:16,196 () INFO  LoggingProxy [RequestProcessor-14347] - invoked: stop_ve_cb(
  "192.168.139.12",
  "Administrator",
  <hidden>,
  "<NAME>",
  java.nio.DirectByteBuffer[pos=0 lim=32 cap=32]
); reqId=88850; corbaReqId=1113178.
.....
2014-02-11 20:13:20,624 (9bcae5d0-aae5-44dd-9066-e42f65869395) ERROR NativeVm2VfCode [Thread-2361296] - [88850:1113178] ERR open_vm_get_uuid2_pipeline(ve_action_cb_ex, start.c, 479): failure: PRL_ERR_VM_UUID_NOT_FOUND @[common/generic_sdk_cb.c][284][generic_sdk_cb][31449])
.....

PRL_ERR_VM_UUID_NOT_FOUND this error mean that Dispatcher can not find container "<NAME>"

On the HW node:

>prlctl list <NAME>
UUID                                    STATUS       IP_ADDR         T  NAME
Failed to get VM config: The virtual machine could not be found. The virtual machine is not registered in the virtual machine directory on this server. Contact your Parallels Server administrator for assistance.

Resolution

Restart Dispatcher to force it reinitialize containers and VMs located on the HW node:

Go to Services > Parallels Dispatcher Service > Restart

>prlctl list <NAME>
UUID                                    STATUS       IP_ADDR         T  NAME
{6f72e018-d3a9-4e00-9a7e-3b3c682bf219}  running      10.127.190.192  CT <NAME>