Article ID: 119141, created on Dec 13, 2013, last review on Jul 27, 2015

  • Applies to:
  • Odin Business Automation Standard

Symptoms

In CP Total Traffic bar is all "Blue" (completed 100%), but used traffic is not too much (Used 0.0 B).

The issue exists for all containers in HW node.

Cause

There are two versions of PVA is installed on the node:

[root@hw_node ~]# rpm -qa | grep release
virtuozzo-release-4.7.0-52
pva-release-4.6-1879
pva-release-6.0-2145

Since container traffic is counted on the node by VZAgent (PVA), this might cause the issue.

Resolution

Complete upgrading of PVA to version 6.0 on the HW node. Refer to these KB articles for more detail:

How to install/reinstall/upgrade PVA Agent on PCS 6, PSBM 5, or PVCfL 4.7 HW Node

Parallels Virtual Automation builds, releases, and supported virtualization products

Search Words

total traffic

traffic usage

400e18f6ede9f8be5575a475d2d6b0a6 caea8340e2d186a540518d08602aa065

Email subscription for changes to this article
Save as PDF