Article ID: 118781, created on Nov 21, 2013, last review on May 18, 2015

  • Applies to:
  • Odin Business Automation Standard

Symptoms

If a container has a lot of IP Addresses (for example, 233 IP addresses assigned) it cannot be synchronized or started from OBAS. The following errors appear in DEBUG OBAS log (/var/log/hspc/hspc.log):

[HSPC::ErrorStack::set_last_error] [ErrorStack]: 131327 VZAgent provisioning error.
[HSPC::VZAgent::Common::error] VZA error occurs: Cannot send packet to node

or

[HSPC::ErrorStack::set_last_error] [ErrorStack]: 65791 VZAgent provisioning error.
[HSPC::MT::OM::VE::_report_problem] Virtuozzo Container: start on Virtuozzo Container # CTID fails with code 255
[HSPC::MT::OM::VE::_report_problem] Error occurred while operating (start) with Virtuozzo Container CTID 

Cause

Such behavior is caused by the software issue PBAS-29153 that was fixed in OBAS 4.5.

Resolution

Upgrade OBAS to the latest version.

Hotfix for OBAS 4.3.4

Hotfix for OBAS 4.3.4 is attached. Download the file and install the hotfix on OBAS 4.3.4 node using the following commands:

~# rpm -Ufv hspc-vzagent-4.3.4-41.swsoft.i386.rpm
~# service hspcd restart