Article ID: 113929, created on May 18, 2012, last review on Nov 2, 2012

  • Applies to:
  • Operations Automation


The Hosted PBX provisioning task for the service sip_device fails with the error message Device Type not found.


An incorrect BroadWorks phone device profile name is configured in the Parallels Operations Automation (POA) Hosted PBX resource.


Check the name of the BroadWorks phone device profile in the POA Hosted PBX resource and adjust, if necessary:
  • Log in to the POA Provider Control Panel.
  • Go to Top > Service Director > Application Manager > Applications > Hosted BroadWorks > Resource Types tab.
  • Click on the resource type based on the resource class Application Service, Service = Phone.
  • Switch to the tab Activation Parameters.
  • Enter the correct value into the field Profile Name.

The parameter "Profile Name" should be set to the correct BroadWorks phone device profile name.

You can see the names of existing Identity/Device Profile Types in the BroadWorks Control Panel:
  • Log in to the BroadWorks CP using your Service Provider login and password.
  • Go to Resources > Identity/Device Profiles.
  • Click the Add button.
  • All available device profiles are listed in the Identity/Device Profile Type field.

caea8340e2d186a540518d08602aa065 5356b422f65bdad1c3e9edca5d74a1ae e12cea1d47a3125d335d68e6d4e15e07

Email subscription for changes to this article
Save as PDF