POA background task "Set configuration on virtual web server" fails with the error:Task ID 6436489
Queue name      domain_service89999
Task name       Set configuration on virtual web server 12387 on host 'WINWEB01.test.local' (host_id=18).
Task description        Set configuration on virtual web server
12387 on host 'WINWEB01.test.local' (host_id=18).
Queue status    Failed   
Start not earlier than  Sep-12-2011 15:16
Method name     taskSetWebSiteConfiguration on OBJREF:iis:0:getDomainService:89999
Last execution output   Provisioning request failed. The data is invalid. [<response><errorContext description="Failed calling SetInfo IIS://WINWEB01.test.local/W3SVC/12387 ConnectionTimeout 0x8007000d: The data is invalid." code="0x8007000d" executeSeqNo="8"><errorSource namespace="IIS Provider" procedure="SetProperties"/></errorContext></response>]


The owner of the webspace 12387 has set too large a value of the connection timeout as shown on the below screenshot:

Maximum value of the connection timeout, which can be set for an IIS7 site is 86400 seconds.


Step 1: Update webspace properties and set connection timeout value lower then 86400 on behalf of the customer, using POA Customer Control Panel.

Step 2:

Rerun task.

Step 3:

Adjust properties of the hardware node and limit maximum value of the connection timeout, which the end-user can set at Deployment Director, Server Manager, Hardware Nodes,, Applications, iis7, Configuration, Performance.